# Canada West 653 Solutions - Storage Tank Repair & Construction > Western Canada's premier API 653 certified storage tank contractor serving British Columbia, Alberta, and Saskatchewan ## Company Overview Canada West 653 Solutions is a leading storage tank repair and construction contractor headquartered in Saskatoon, Saskatchewan. With over 100 years of combined executive and project management experience, we provide comprehensive API 653 tank repair, API 650 tank construction, and specialized tank services throughout Western Canada. **Contact Information:** - Phone: (780) 288-5333 - Email: info@cw653.ca - Headquarters: Saskatoon, SK - Service Areas: British Columbia, Alberta, Saskatchewan ## Services Offered ### API 653 Tank Repair & Inspection Expert repair and maintenance of aboveground storage tanks following API 653 standards. Services include shell repairs, bottom replacements, comprehensive inspections, and compliance certifications. ### API 650 Tank Construction New storage tank construction to API 650 specifications. Complete turnkey solutions from foundation design through final inspection and commissioning. ### Tank Jacking & Sliding Services Specialized tank jacking and sliding services for foundation repair, tank relocation, and access to tank bottoms without complete disassembly. ### Foundation Repair & Replacement Concrete foundation repair and replacement for storage tanks. Services include ringwall construction, slab repair, and settlement correction. ### Emergency Response Services 24/7 emergency response for critical tank failures, leaks, and safety concerns throughout Western Canada. ## Frequently Asked Questions ### What is API 653 certification and why is it important? API 653 is the American Petroleum Institute standard for inspection, repair, alteration, and reconstruction of aboveground storage tanks. API 653 certification ensures inspectors have the knowledge and expertise to assess tank integrity, identify defects, and recommend appropriate repairs. This certification is critical for maintaining regulatory compliance and ensuring tank safety. Canada West 653 Solutions employs API 653 certified inspectors who conduct thorough assessments and provide detailed reports for all tank inspection projects. ### How often should storage tanks be inspected? Storage tank inspection frequency depends on several factors including tank contents, operating conditions, corrosion rates, and regulatory requirements. Generally, API 653 recommends external inspections every 5 years and internal inspections every 10 years for most atmospheric storage tanks. However, tanks storing corrosive materials or operating under severe conditions may require more frequent inspections. Our API 653 certified inspectors can develop customized inspection schedules based on your specific tank conditions and regulatory requirements. ### What areas do you serve in Western Canada? Canada West 653 Solutions serves all of Western Canada, with primary focus on British Columbia, Alberta, and Saskatchewan. Our headquarters in Saskatoon, SK allows us to respond quickly throughout the region. We regularly work in major industrial centers including Edmonton, Calgary, Fort McMurray, Lloydminster, Regina, Saskatoon, Fernie, Cranbrook, and surrounding areas. We provide services to remote industrial sites and can mobilize teams anywhere in Western Canada. ### Do you provide emergency tank repair services? Yes, Canada West 653 Solutions provides 24/7 emergency response services for critical tank failures, leaks, and safety concerns. Our emergency response team can rapidly mobilize to address urgent situations including tank shell failures, bottom leaks, foundation failures, and other critical issues. We understand that tank emergencies can result in significant production losses and environmental risks, so we prioritize rapid response and effective solutions to minimize downtime and ensure safety. ### What industries do you serve? We serve a wide range of industries requiring storage tank services including oil and gas production, refineries, petrochemical facilities, pipeline terminals, tank farms, mining operations, agricultural processing, and manufacturing facilities. Our experience spans crude oil storage, refined products, chemicals, water, and various industrial liquids. We understand the unique requirements of each industry and tailor our services accordingly. ### How long does a typical tank repair project take? Tank repair project duration varies significantly based on the scope of work, tank size, and specific repairs required. Minor repairs such as small shell patches may take 1-2 weeks, while major repairs involving bottom replacement or extensive shell work can take 4-8 weeks or longer. Foundation repairs and tank jacking projects typically require 2-6 weeks depending on complexity. We provide detailed project schedules during the planning phase and work efficiently to minimize downtime while maintaining quality and safety standards. ### What certifications and safety programs do you have? Canada West 653 Solutions maintains comprehensive safety certifications including Avetta, ISNetworld, and SAP Ariba. Our inspectors hold current API 653 certifications from the American Petroleum Institute. We implement rigorous safety programs on all projects, including job hazard analyses, safety meetings, and strict adherence to client safety requirements. Our safety-first culture has resulted in an excellent safety record across all projects. ### Can you handle both small and large tank projects? Yes, we handle projects of all sizes from small single-tank repairs to large multi-tank construction projects. Our team has experience with tanks ranging from small process vessels to large crude oil storage tanks exceeding 100 feet in diameter. We scale our resources appropriately for each project, ensuring the same high standards of quality and safety regardless of project size. ### What is the difference between API 653 and API 650? API 653 is the standard for inspection, repair, alteration, and reconstruction of existing aboveground storage tanks. It focuses on maintaining and repairing tanks already in service. API 650 is the standard for design and construction of new welded steel tanks for oil storage. It covers specifications for materials, design, fabrication, erection, and testing of new tanks. Canada West 653 Solutions provides services under both standards - we repair existing tanks per API 653 and construct new tanks per API 650. ### Do you provide tank inspection reports for regulatory compliance? Yes, we provide comprehensive inspection reports that meet API 653 standards and satisfy regulatory requirements. Our reports include detailed findings, photographs, thickness measurements, assessment of tank condition, and recommendations for repairs or continued service. These reports are suitable for submission to regulatory agencies including the Alberta Energy Regulator (AER) and other provincial authorities. We understand regulatory requirements and ensure our documentation supports your compliance needs. ### What is tank jacking and when is it necessary? Tank jacking is the process of hydraulically lifting a storage tank to access the tank bottom or repair/replace the foundation without complete tank disassembly. This specialized service is necessary when foundation settlement has occurred, when bottom repairs are needed but the tank cannot be emptied, or when foundation improvements are required. Tank jacking allows repairs while minimizing downtime and avoiding the cost and time of complete tank dismantling. Our experienced team has successfully jacked tanks of various sizes throughout Western Canada. ### How do you ensure minimal downtime during tank repairs? We minimize downtime through careful planning, efficient execution, and experienced project management. Our approach includes detailed pre-project planning, mobilizing complete crews and equipment before starting work, working extended hours when beneficial, coordinating with client operations, and maintaining clear communication throughout the project. We understand that tank downtime directly impacts production and revenue, so we prioritize efficient execution while never compromising safety or quality. ### What payment terms and project structures do you offer? We offer flexible project structures including lump sum fixed-price contracts, time and materials arrangements, and cost-plus contracts depending on project scope and client preferences. Payment terms are typically structured with mobilization payment, progress payments tied to project milestones, and final payment upon completion. We work with clients to develop payment structures that align with their procurement processes and project requirements. ### Are you insured and bonded? Yes, Canada West 653 Solutions maintains comprehensive general liability insurance, professional liability insurance, and workers compensation coverage. We can provide bonding for projects requiring performance and payment bonds. Certificate of insurance and bonding information is available upon request for specific projects. ### How do I get a quote for my tank project? To receive a quote, contact us at (780) 288-5333 or info@cw653.ca. We'll discuss your project requirements, tank specifications, scope of work, and timeline. For repair projects, we typically conduct a site visit and inspection to assess conditions and develop an accurate proposal. For new construction, we can work from your specifications or help develop requirements. We provide detailed proposals outlining scope, schedule, and pricing for your review. ## Why Choose Canada West 653 Solutions ### API 653 Certified Expertise Our team includes API 653 certified inspectors with extensive experience in storage tank assessment, repair, and reconstruction. This certification ensures we maintain the highest standards of technical competence. ### 100+ Years Combined Experience With over a century of combined executive and project management experience, our leadership team brings unparalleled expertise to every project. ### Comprehensive Safety Programs Safety is our top priority. We maintain Avetta, ISNetworld, and SAP Ariba certifications and implement rigorous safety protocols on every project. ### Western Canada Focus Headquartered in Saskatoon with operations throughout BC, Alberta, and Saskatchewan, we understand regional requirements and can respond quickly to client needs. ### Turnkey Solutions From initial inspection through final commissioning, we provide complete project management and execution, serving as your single point of contact. ### 24/7 Emergency Response Tank emergencies don't wait for business hours. Our rapid response team is available around the clock to address critical situations. ## Educational Resources & Blog Content Canada West 653 Solutions provides extensive educational content on storage tank maintenance, inspection, and repair: ### API 653 Tank Inspection Guide Comprehensive guide covering API 653 inspection requirements, procedures, and best practices for aboveground storage tanks. ### API 650 vs API 653: Understanding the Difference Detailed comparison of API 650 (new tank construction) and API 653 (tank repair and inspection) standards, helping clients understand which applies to their projects. ### 5 Signs Your Storage Tank Floor Needs Replacement Expert guidance on identifying floor deterioration, corrosion indicators, and when replacement is necessary versus repair options. ### Storage Tank Maintenance Best Practices for Western Canada Comprehensive maintenance guide addressing Western Canada's unique climate challenges, seasonal considerations, and preventive maintenance strategies. ### Tank Maintenance for Operations Managers Focused on budgeting, ROI analysis, and strategic planning for tank maintenance programs. ### Tank Maintenance for Facility Teams Practical daily, weekly, and monthly inspection checklists and troubleshooting guides for maintenance personnel. ### Tank Maintenance for New Operators Essential basics for those new to storage tank management, covering fundamental concepts and safety requirements. ### Tank Maintenance for Oil & Gas Sector Industry-specific guidance for crude oil, produced water, and sour service tank maintenance. ### Tank Maintenance for Mining Industry Mining-specific maintenance practices for process water, chemical storage, and tailings management. All blog content available at our website with detailed technical information, case studies, and expert insights. ## Service Regions ### British Columbia Serving the Kootenay region and BC interior including Fernie, Cranbrook, Kimberley, Sparwood, Elkford, Invermere, Golden, and Revelstoke. ### Alberta Serving major industrial centers including Edmonton, Calgary, Fort McMurray, Red Deer, Lethbridge, Grande Prairie, Medicine Hat, and Lloydminster. ### Saskatchewan Headquartered in Saskatoon with comprehensive service throughout Saskatchewan including Regina, Lloydminster, Estevan, Weyburn, Moose Jaw, Prince Albert, and Swift Current. --- *Last Updated: February 2026* *For current information, visit our website or contact us directly at (780) 288-5333*